-51-

-14-

SETTING THE PIR DETECTORS
Located on the PCB of the PIR Detector is a two-position DIP switch (SW2).
When conducting the Walk Test, ensure that the DIP switch SW2 is set as
follows:

1. DIP1 of SW2 is used to configure the PIR Detector for walk test mode, which

allows the operation of the detector to be checked during installation without
triggering a Full Alarm.

ON

Walk Test mode

OFF Normal mode

Note: On initial installation the detector should be set into Walk Test mode
ready for testing. Upon completion of Walk Test mode, set DIP1 of SW2 to
OFF for normal detection mode.

2. The PIR Detector incorporates an anti-false alarm feature designed to

compensate for situations where the detector may be affected by
environmental changes, (e.g. insects, air temperature, etc). This feature is
called “sensitivity detection” and may be selected for high or low detection.

The recommended setting is for high sensitivity detection. However, in cases
of extreme environmental problems or if unattributable false alarms are
experienced, it may be necessary to select low sensitivity detection.

Set the required sensitivity detection using DIP2 of SW2 as follows:

ON

high sensitivity detection

OFF low sensitivity detection

Note: The higher the sensitivity detection the less movement will be
necessary before the PIR detector will trigger the alarm.

SW2

DIP1

DIP2

ON
OFF

DIP-switch
(SW2)

EXIT DELAY
Scroll through the menu until ‘7-1 Exit Delay’ is displayed. The current setting
will also be displayed.

Default setting: ON, 30s
To change the setting press .

Press to enable the Exit delay and enter the required exit delay period
(1-250s), or
Press to disable the Exit delay.

Press to save and exit, or
Press to exit without saving.

ENTRY DELAY BEEP
This controls the warning beep which operates during the Entry Delay period
when Partial Arm 2 is active.

Default setting: ON

Scroll through the menu until ‘:7-2 Entry Delay Beep’ is displayed. The current
setting will also be displayed.

To change the setting press .

Press to enable the Entry-delay beep, or
Press to disable the Entry-delay beep.

PROGRAM MODE

Code

7. PARTIAL

ARM2

7-1 Exit Delay

xx xxx SEC

Select

ON->* OFF->#

Select

ON->* OFF->#

Input (1-250) Secs

7-2 Entry Delay

Beep: xxx

7-3 Exit Delay

Beep: xxx

EN

EN

Select

ON-> OFF->#