-19-

-46-

If setting the DIP1 & DIP2 to ‘Off’, only the internal contact will be active.
When two contacts are in use for internal and external connection simulta-
neously, one activation will be counted if one of the contacts is opened; while
both contacts must be all close, the Detector will then be treated as close.

3. If external contacts are wired to the Detector, set the DIP1 to ‘Off’ and DIP2

to ‘On’.

IMPORTANT: If external contacts are not connected, set the DIP1 to ‘On’ and
DIP2 to ‘Off’ for the detector to operate correctly.

4. In order to communicate with the Control Panel, the ID code of the Detector

needs to be learned by the Control Panel. By pressing the tamper switch
either located adjacent to the PCB or rear cover of the Detector will emit the
ID code to the Control Panel instantly, subject to the Control Panel being set
at the Zone setup mode.

TESTING THE MAGNETIC CONTACT DETECTORS
Ensure that the system is in Test Mode

1. Use the and buttons to scroll through the menu until ‘WALK TEST

is displayed.

Press to activate Walk Test. ‘Walk Test Waiting…’ will be displayed.

2. Remove the battery cover by sliding off.

As the battery cover is removed the LED on the Detector will illuminate for
approx. 1 second to indicate that the tamper switch has been activated.
In addition, the Control Panel will beep to indicate that an alarm signal has
been received and ‘Magnetic Contact Tamper’ will be displayed.

3. Open the door/window to detach the magnet from the Detector. As the

magnet is parted from the detector the LED will illuminate for approx. 1
second to indicate that the Detector has been triggered. In addition, the
Control panel will beep to indicate that an alarm signal has been received and
the identity of the zone that the detector is set for will be displayed.

Note: In normal mode with the battery cover fitted, the LED on the detector
will not illuminate when the detector is triggered, (unless the battery is low).

4. If connected, operate the wired Magnetic Contact. As the contact is opened

the LED on the Detector should illuminate for 1 second to indicate that it has
been triggered and the Control Panel will acknowledge the alarm signal.

5. Refit the battery cover on the Detector.

6. Press to return to the top level menu of TEST MODE.

REMOTE TELEPHONE CONTROL

Scroll through the manual until ‘:1 Remote TEL Control’ is displayed and
press .

Default setting: OFF

To change the setting press .

Press to enable the Remote Telephone control, or
Press to disable the Remote Telephone control.

NUMBER OF DIALING CALL
This facility controls the number of dialing call via the connected telephone line.

Default setting: one call

Scroll through the manual until ‘:2 Remote Type’ is displayed and press .

To change the setting press .

Scroll through available options (e.g. one call & double call) until the required
setting is displayed.

ONE CALL
The number of ring for the Control Panel must be greater than that of the set
number of rings. By doing so, the Control Panel will answer the call and emit
three beeps on the phone line to prompt for a User Password to be entered
using the telephone keypad.

DOUBLE CALL
This feature is suitable for use when the fax or answer phone is connected to
Control Panel externally. The procedure is as follows:

1. Dial up the system and hang up after two rings.
2. Redial up the system within 28s as maximum (14s as minimum), subject to

the interval of ring being entered at 13s, the system will pickup the phone
after 1 ring.
Note: The maximum and minimum period for redialing up the system will
vary depending on the interval of ring you entered. Refer to ‘INTERVAL OF
RING FOR DOUBLE CALL
’ for better comprehension.

3. Enter the User Password as normal.

NUMBER OF RINGS FOR ONE CALL
The number of rings for one call must be set within 2-9

EN