ELRO HA68S Multi-zone professional alarm system USERS MANUAL User Manual
Page 32

To change the setting press .
Press to enable the Auto Report function, or
Press to disable the Auto Report function.
JAMMING DETECTION
This feature controls the Control Panels RF jamming detection circuitry, which if
enabled, will continuously scan for radio jamming signals on the system
operating frequency.
Default setting: OFF
Scroll through the menu until ‘2-5 RF Jamming’ is displayed. The current
setting will also be displayed.
To change the setting press .
Press to enable Jamming Detection, or
Press to disable Jamming Detection.
CONTROL PANEL BACK LIGHT
This controls the time period that the backlight for the Control Panel display will
stay illuminated for after the last key is pressed.
Default setting: 10s
Scroll through the menu until ‘2-6 Back Light’ is displayed. The current setting
will also be displayed.
To change the setting pres s .
Scroll through available options, (10, 20, 30 and 60s) until the required setting
is displayed.
Press to save and exit, or
Press to exit without saving.
WARNING BEEP
When any abnormal conditions have occurred such as the system being
triggered or detectors’ low battery, the ‘ALARM MEM’ LED on the Control Panel
will be on accompanying warning beep as a reminder. This feature, if enabled,
allows the Control Panel to be emitted a warning beep periodically once
abnormal conditions is occurred.
If when the system is disarmed the ‘ALARM MEM’ LED is flashing and the Control
Panel beeps periodically, this indicates that an alarm has occurred. To cancel
the LED and stop the beeping you must access the event log or press to
eliminate the flashing ‘ALARM MEM’ LED and the beeping as well.
-35-
-30-
PROGRAM MODE
Code:
3. ZONE SETUP:
3-1 Set 1-36
Zone
Input (01-36)
Zone Number
:1 Learning ID
Learning
Intruder
24 hour Intruder
Fire
Medical help
Panic
Learning OK
Time Out
ID Duplicate
:2 Zone Name
xxxxxxxxxxxxxx
:3 Zone Type
xxxxxxxxxxxxxx
:4 Zxx Chime
Mode xxxx
:5 Zxx ENTRY
DELAY: XXX XXX
:6 Zxx
PARTIAL ARM 1:
:7 Zxx
PARTIAL ARM 2:
:8 Magnetic
O/C Detector xxx
:9 Auto Report
:10 Zone Status
:11 Zone Reset
:12 Zone Siren
Select
ON->* OFF->#
Select
ON->* OFF->#
Select
ON->* OFF->#
Select
ON->* OFF->#
Select
ON->* OFF->#
Select
ON->* OFF->#
Select
ON->* OFF->#
Input
(01-25)*10Sec.
Select
ON->* OFF->#
Select
ON->* OFF->#
No name
Front door
Back door
Patio door
Dining room
Living room
Lounge
Kitchen
Shed
Garage
Hall
Landing
Upstairs
Downstairs
Bedroom 1
Bedroom 2
Bedroom 3
Bedroom 4
Windows 1
Windows 2
Windows 3
PIR Detector
Magnetic Contact
FIRE/SMOKE
Panic/PA
Medical
ZONE SETUP
Scroll through the programming menu until ‘3. ZONE SETUP’ is displayed and
press .
Enter the zone number to be configured and press .
The following configuration options are based upon configuring zone 1. Options
for all other zones (2-36) are identical except the zone number reference will
change according to the zone being configured.