Hydrotech PURA ADDON SERIES User Manual

Page 13

Advertising
background image

8

UVBB SERIES - SYSTEM ASSEMBLY AND ACTIVATION PROCEDURES

PREPARATION – INSPECT ALL PARTS

NOTE:

Read Mounting Bracket and System Plumbing
Installation instructions on Page 1 and all instructions
on this page before installing system.

NOTE:

See Page 10 for UVBB detailed parts breakdown.

Refer to label affixed to the mounting bracket to

identify filter(s) to be installed with UV module.

CONTROL MODULE INSTALLATION

INSTALL QUARTZ SLEEVE AND DISINFECT SYSTEM

Check page 20 for pictures of Quartz Sleeve.

CAUTION:

QUARTZ SLEEVE IS VERY FRAGILE!
For safety, wear a protective glove when handling
quartz sleeve. Do not touch quartz sleeve or UV
lamp with bare hands. Fingerprints will reduce the
effectiveness of the light.

NOTE:

All Items refer to Figure 3.

1. Remove Sump (Item 1) from UV Head (Item 5).

NOTE:

A band of Red Tape (Item 23) is affixed to quartz
sleeve approximately 3” from the top. Do not remove
this tape until so instructed. Do not remove protective
plastic bag from quartz sleeve until so instructed.

2. Remove Quartz Sleeve (Item 17) from packing tube. While

holding middle of quartz sleeve with one hand, slide protective
bag with other hand to expose open end.

3. Place a small amount of silicone based “O” ring lubricant on the

outside of the open end of the quartz sleeve only on the area that
will engage with the “O” ring.

CAUTION:

Apply even pressure to push the quartz sleeve into
Quartz Adapter Sleeve (Item 4). To avoid breakage,
make sure quartz sleeve goes in straight by pushing it
with a slight twisting motion.

4. Insert quartz sleeve into quartz adapter sleeve until the top of red

tape meets the bottom of the quartz adapter sleeve.

NOTE:

Quartz Adapter Sleeve (Item 4) is factory installed into
the UV Head (Item 5).

5. Remove Red Tape (Item 23) and protective bag from quartz

sleeve.

NOTE:

Wipe all fingerprints and excessive lubricant from
quartz sleeve with isopropyl alcohol.

6. For UVBB-2 and UVBB-3 Models only: Remove Sump (Item 1)

from Filter Head (Item 20). Remove Filters (Items 21 and 22) from
sump and set aside.

7. Disinfect the system (Pages 18-19, Steps 1-7).

INSTALL ULTRAVIOLET LIGHT AND FILTERS

CAUTION:

TIGHTEN SUMPS BY HAND ONLY. Do not use tools
as they will over-tighten and may damage sump. Take
care not to cut or pinch “O” Rings (Item 2). Use sump
wrench for removal only.

8. For UVBB-2 and UVBB-3 Models only: Remove Sump (Item

1) from Filter Head (Item 20). Install Filters (Items 21 and 22) as

shown in Figure 3. Install sump onto filter head.

CAUTION: DO NOT INSTALL A DAMAGED LAMP

INSTALL CONTROL MODULE AND UV LAMP

NOTE:

Hold UV lamp by ceramic ends only. Do not touch the
glass. Clean with isopropyl alcohol if necessary.

9. Remove UV Lamp (Item 16) from packing tube and inspect it for

damage. If damage is found, contact the dealer for a replacement.

10. Unpack the carton box and verify that all the required

components have been received.

The UVBB control module installation kit includes:

a) Control Module – Qty 1

b) Screws , 6/32 X 3/8” (Part# 32701063) - Qty 4

c) Washer, Lock , #8 (Part# 12288) - Qty 1

d) Installation Guide (#54752)

11. Connect UV lamp into four-pin socket that is connected to the

UV control module by a cable that allows for correct insertion
depth.

12. Carefully insert the UV control module with UV lamp through

mounting bracket into the quartz sleeve making sure the cable
does not twist or curl.

13. Install the UVBB control module on top of the ultraviolet

disinfection system’s bracket with four screws and one lock
washer (for grounding purpose) as shown in the Figure* 3A.

UVBB SERIES

UVBB Ultraviolet System
Control Module Box
Ultraviolet Lamp #20 (in packing tube)
Quartz Sleeve #22 (in packing tube)
Mounting Screws (2-4 pieces, varies with model)
Installation Manual and Owners Guide
Sump Wrench #20BB

Figure 3A - * UVBB-3 model shown

Advertising
This manual is related to the following products: