ROUTINE MAINTENANCE

It is important that any water treatment system be properly maintained to ensure consistent water quality. The information provided on this
page is of a general nature. See Cleaning, Disinfecting, and Routine Maintenance Procedure on Page 18 and 19 for detailed information.
Refer to Mounting Bracket and System Plumbing Installation Instructions on Page 1, and the appropriate System Assembly and Activation

Procedures for detailed information to install your specific PURA system.

Cleaning: The inside of the system and the quartz sleeve should be

cleaned each time the filters are changed. Clean all parts (except

the filters and electronic parts) with soap and rinse them thoroughly
with clean potable water. Dry the inside of the quartz sleeve
thoroughly before re-assembling system.

NOTE:

Presence of iron or general poor water quality will
require frequent inspection and cleaning.

“O” Rings: Lubricate each “O” ring with a silicone based “O” ring

lubricant to ensure a proper seal.

NOTE:

UV lamp should remain on at all times during use
because; repeated starting of UV lamp shortens lamp
life, and UV lamp requires a warm up period of 1-2
minutes.

Filter Replacement: Filters will normally last approximately four to
six months. Filter life will vary due to water conditions. A reduced

flow rate or deteriorating water quality indicates that filters must be
changed.

Use only PURA filters. PURA filters are specially designed to work

in the ultraviolet disinfection process. Use of non-PURA filters voids
the warranty.

CAUTION:

Use care when changing the filters to avoid breaking

the quartz sleeve.

UV Lamp Replacement: Lamps must be changed every twelve
months. While UV lamps rarely burn out, they do lose their

disinfection power. Use only PURA UV lamps as they are specifically
designed for the PURA system to deliver high quality drinking water.

PURA ULTRAVIOLET SPECIFICATIONS

Model

Shipping

Weight

lbs. (kg)

Dimensions◊

Inches (Centimeters)

Height x Width x Depth

Flow Rate

Gallons Per Minute

Liters per Minute

Lamp Type &

Power Used

Watts

Inlet/ Outlet

UVB1

10.0 lbs. (4.5 kg)

15.0” x 5.5” x 5.5”

(38.1 cm x 14.0 cm x 14.0 cm)

2 gpm (7.6 L/min)

UV Lamp #11

14 Watts

3/8” NPT

UVB2

15.0 lbs. (6.8 kg)

15.0” x 11.0” x 5.5”

(38.1 cm x 27.9 cm x 14.0 cm)

UVB3

24.0 lbs. (10.9 kg)

15.0” x 16.0” x 5.5”

(38.1 cm x 40.6 cm x 14.0 cm)

UV20-1

16.0 lbs. (7.3 kg)

25.0” x 5.5” x 5.5”

(63.5 cm x 14.0 cm x 14.0 cm)

10 gpm (38 L/min)

UV Lamp #20

22 Watts

3/4” NPT

UV20-2

24.0 lbs. (10.9 kg)

25.0” x 11.0” x 5.5”

(63.5 cm x 27.9 cm x 14.0 cm)

UV20-3

32.0 lbs. (14.5 kg)

25.0” x 16.0” x 5.5”

(63.5 cm x 40.6 cm x 14.0 cm)

8 gpm (30 L/min)

UVBB-1

20.0 lbs. (9.1 kg)

29.5” x 7.5” x 9.0”

(74.9 cm x 19.0 cm x 22.9 cm)

15 gpm (57 L/min)

UV Lamp #20

22 Watts

1-1/2” NPT

UVBB-2

35.0 lbs. (15.9 kg)

28.0” x 15.0” x 9.0”

(71.1 cm x 38.1 cm x 22.9 cm)

UVBB-3

53 lbs. (24.0 kg)

28.0” x 23.0” x 9.0”

(71.1 cm x 58.4 cm x 22.9 cm)

UV1

7.0 lbs. (3.2 kg)

13.5” x 5.0” x 5.0”

(34.3 cm x 12.7 cm x 12.7 cm)

1 gpm (3.8 L/min)

UV Lamp #10

10 Watts

1/2” NPT

UV A/O-1

5.0 lbs. (2.3 kg)

12.0” x 4.0” x 3.5”

(30.5 cm x 10.2 cm x 8.9 cm)

1 gpm (3.8 L/min)

UV Lamp #10

10 Watts

3/8 QC

UV A/O-3

7.0 lbs. (3.2 kg)

22.5” x 4.0” x 3.5”

(57.2 cm x 10.2 cm x 8.9 cm)

3 gpm (11.4 L/min)

UV Lamp #20

22 Watts

† Female thread as recognized by United Sates National Pipe Thread.
‡ Push-in Quick Connectors or Quick Connectors (QC).