UVB SERIES - SYSTEM ASSEMBLY AND ACTIVATION PROCEDURES

PREPARATION – INSPECT ALL PARTS

NOTE:

Read Mounting Bracket and System Plumbing
Installation instructions on Page 1 and all instructions
on this page before installing system.

NOTE:

See Page 4 for UVB detailed parts breakdown. Refer

to the label affixed to the mounting bracket to identify

filter(s) to be installed with UV module.

CONTROL MODULE INSTALLATION

CONTROL MODULE INSTALLATION WITH SAFETY ROD FOR
UVB MODELS WITHOUT THE LOC OPTION

INSTALL QUARTZ SLEEVE AND DISINFECT SYSTEM

Check page 20 for pictures of Quartz Sleeve.

CAUTION:

QUARTZ SLEEVE IS VERY FRAGILE!
For safety, wear a protective glove when handling
quartz sleeve. Do not touch quartz sleeve or UV
lamp with bare hands. Fingerprints will reduce the
effectiveness of the light.

NOTE:

All Items refer to Figure 1.

1. Remove Sump (Item 1) from UV Head (Item 5).
NOTE:

Do not remove protective plastic bag from quartz
sleeve until so instructed.

2. Remove Quartz Sleeve (Item 17) from packing tube. While

holding middle of quartz sleeve with one hand, slide protective
bag with other hand to expose open end.

3. Place a small amount of silicone based “O” ring lubricant on the

outside of the open end of the quartz sleeve only on the area that
will engage with the “O” ring.

CAUTION:

Apply even pressure to push the quartz sleeve into the
UV head. To avoid breakage, make sure quartz sleeve
goes in straight by pushing it with a slight twisting
motion.

4. Insert quartz sleeve into the UV head. As quartz sleeve passes

the “O” Ring (Item 15), resistance will be felt. Remove protective
bag from quartz sleeve.

5. Remove EPCB™ Carbon Filter (Item 3) and EPCB™ Sleeve

(Item 24) from sump and set aside.

6. For UVB2 and UVB3 Models only: Remove Sump (Item 1) from

Filter Head (Item 20). Remove Filters (Items 21 and 23) from
sump and set aside.

7. Disinfect the system (Pages 18-19, Steps 1-7).

INSTALL ULTRAVIOLET LIGHT AND FILTERS

1. Remove Sump (Item 1) from UV Head (Item 5).
NOTE:

Wipe all fingerprints and excessive lubricant from
quartz sleeve with isopropyl alcohol.

2. Install EPCB™ Sleeve (Item 24) into EPCB™ Carbon Filter (Item

3) as shown in Figure 1.

3. Insert filter/sleeve assembly into sump as shown in Figure 1 with

both Filter Gaskets (Item 4) in place.

CAUTION:

TIGHTEN SUMPS BY HAND ONLY. Do not use tools
as they will over-tighten and may damage sump. Take
care not to cut or pinch “O” Rings (Item 2). Use sump
wrench for removal only.

4. Being careful not to dislodge quartz sleeve, install sump with filter/

sleeve assembly onto UV head.

5. For UVB2 & UVB3 Models only: Remove Sump (Item 1) from

Filter Head (Item 20). Install Filters (Items 21 and 23) as shown in

Figure 1. Install sump onto filter head.

CAUTION: DO NOT INSTALL A DAMAGED LAMP

INSTALL CONTROL MODULE AND UV LAMP

NOTE:

Hold UV lamp by ceramic ends only. Do not touch the
glass. Clean with isopropyl alcohol if necessary.

6. Remove UV Lamp (Item 16) from packing tube and inspect it for

damage. If damage is found, contact the dealer for a replacement.

UVB SERIES

UVB Ultraviolet System
Control Module Box
Ultraviolet Lamp #11 (in packing tube)
Quartz Sleeve #11 (in packing tube)
Mounting Screws (2-4 pieces, varies with model)
Installation Manual and Owners Guide
Sump Wrench #10/20

Figure 1A - * UVB-3 model shown

Figure 1B - * UVB-3 model shown