Hydrotech PURA ADDON SERIES User Manual

Page 24

Advertising
background image

19

4. Slowly open the feed water supply valve.

5. Open all downstream faucets. Keep faucets open until a chlorine

smell is detected at each faucet, then close faucets.

NOTE: Water lines downstream from UV housing must be

disinfected to destroy any bacteria that might remain in the
pipes.

6. Verify disinfection solution has reached every water outlet

downstream of UV system. Solution must remain in the system
for at least four hours.

7. Open outlet valve and let water flow for 5 minutes to flush

disinfection solution from the water lines.

ROUTINE MAINTENANCE

FILTER REPLACEMENT PROCEDURE

1. Perform Cleaning Procedure (Page 18, steps 1-11).

NOTE:

Do not remove protective plastic bag from filters. Open

bottom of bag only enough to expose bottom of filter.

NOTE:

Refer to Exploded Schematic for your system to

ensure each filter is installed in the correct position.

NOTE:

For UVB and UV1 Models only: Refer to the
Exploded Schematic to ensure proper position of

Teflon Sleeve removed in Cleaning Procedure.

2. Install the filters into the appropriate sump. Hold filter by its

protective plastic bag and insert the filter into the sump.

CAUTION:

For UVBB Model only: Be sure sump with metal liner
is installed onto UV head.

CAUTION:

TIGHTEN SUMPS BY HAND ONLY. Do not use tools
as they will over-tighten and may damage sump. Take
care not to cut or pinch “O” rings or gaskets. Use
sump wrench for removal only.

3. Slide bag from filter and discard. Replace each sump as each

filter is installed.

4. Plug system into electrical outlet. Turn on water supply and check

for leaks. Flush system for several minutes to remove carbon

fines.

ROUTINE MAINTENANCE

UV LAMP REPLACEMENT PROCEDURE

NOTE:

Refer to individual System Assembly and Activation

Procedures to identify specific components matching
the descriptions shown in this procedure.

1. Disconnect system from electrical outlet.

2. Shut feed water supply valve and open downstream faucet to

relieve system pressure.

CAUTION:

Do not attempt to remove sumps until water flow

stops. This reduces pressure inside the system so
sumps may be safely removed.

CAUTION:

Use care when sanitizing UV head. Do not get the UV
control module or connectors wet.

3. Remove sump from UV head and set aside.

CAUTION:

Do not touch quartz sleeve or UV lamp with bare
hands. Fingerprints will reduce the effectiveness of the
light.

WARNING:

Do Not Attempt to Remove Quartz Sleeve.

Damage to system and personal injury may occur if
the sleeve is removed incorrectly. Contact your dealer
if quartz sleeve is broken or needs replacement.

4. Clean quartz sleeve carefully using vinegar to remove hardness.

Do not use abrasive materials. Rinse sleeve thoroughly with clean
potable water. Replace any sleeve that is damaged or that will not
come completely clean.

5. Gain access to UV lamp:

a. For UVB, UV20, and UVBB Models only: Remove UV

Control Module (Item 10) from Mounting Bracket (Item 6,
6A, 6B) by removing four Screws (Item 11).

b. For UV1 Model only: Loosen Screw (Item 9) securing

slotted side of UV Lamp Retainer (Item 7). Remove other
screw securing UV lamp retainer to UV head. Rotate
bracket away from UV lamp. Remove and slide Finish Cap
(Item 12) on cable towards UV control.

6. Remove UV lamp from system being careful not to break UV lamp

or dislodge quartz sleeve:

a. For UVB and UV20 Models only: Remove UV control

module with UV lamp by gently lifting control module

straight up from mounting bracket. Grasp UV lamp firmly
and remove lamp from the four-pin socket.

b. For UVBB Model only: Remove UV control module with

UV lamp by lifting the control module straight up from
mounting bracket. The four-pin socket is attached to the
UV control module by a short cable that allows for correct

insertion depth. Grasp UV lamp and four-pin socket firmly
and separate lamp from connector.

c. For UV1 and Addon Models Only: Remove UV lamp by

gently lifting the cable connecting the four-pin socket to the

UV lamp. Grasp UV lamp and four-pin socket firmly and
separate lamp from connector. During replacement, be
sure UV lamp is inserted as far as possible into the quartz
sleeve.

NOTE:

The inside of quartz sleeve must be completely dry
before installing the replacement UV lamp.

NOTE:

Hold replacement UV lamp by the ceramic ends only.
Do not touch the glass. Clean glass with isopropyl
alcohol if necessary.

7. Install the replacement UV lamp by reversing steps 5 and 6 of this

procedure.

CLEANING, DISINFECTING, AND ROUTINE MAINTENANCE PROCEDURE Cont’d