Hydrotech PURA ADDON SERIES User Manual

Page 25

Advertising
background image

20

INSTALL QUARTZ SLEEVE

CAUTION: QUARTZ SLEEVE IS VERY FRAGILE!

For safety, wear a protective glove when handling
quartz sleeve. Do not touch quartz sleeve or UV
lamp with bare hands. Fingerprints will reduce the
effectiveness of the light.

1. Remove Sump from UV Head.

NOTE:

Do not remove protective plastic bag from quartz sleeve
until so instructed.

2. Remove Quartz Sleeve from packing tube. While holding middle of

quartz sleeve with one hand, slide protective bag with other hand
to expose open end.

3. Place a small amount of silicone based “O” ring lubricant supplied

in the small packet on the outside of the open end of the quartz
sleeve only on the area that will engage with the “O” ring.

CAUTION: Apply even pressure to push the quartz sleeve into the

UV head. To avoid breakage, make sure quartz sleeve
goes in straight by pushing it with a slight twisting motion.

4. Insert quartz sleeve into the UV head. As quartz sleeve passes “O”

Rings, resistance will be felt. Remove protective bag from quartz
sleeve.

O-RING REQUIRED FOR QUARTZ SLEEVE REPLACEMENT

Replacement

Quartz
Sleeve

UV

Model

Number

# of O-Ring

in Old Style

UV Cap

# of O-Ring

in New Style

UV Cap

Date of

Change

36003033

UV1

2

2

1st May, 2007

36003034

UVB

2

1

9th April, 2009

36003034

ADDON1

2

2

No Change

36003035

UV20

2

1

8th May, 2009

36003035

ADDON3

2

2

No Change

36003036

UVBB

3

3

15th October,

2008