2 - wiring the motors – CAME Frog-AEP24 Kit User Manual

Page 10

Advertising
background image

2.2 - Wiring the Motors

THE FROG MOTORS ALWAYS COME PREWIRED AND THE CONNECTIONS TO THE MOTOR
SHOULD BE MADE IN THE JUNCTION BOXES AT THE BASE OF THE GATE POST (I.E OUT OF
THE GROUND OR FOUNDATION CASING) AS SHOWN IN FIG 3.

UNDER NO CIRCUMSTANCES MUST THE MOTOR BE DISCONNECTED FROM THE GEARBOX
AS THIS WILL INVALIDATE THE WARRANTY.

WHEN CONNECTING THE MOTORS TO THE CONTROL PANEL THE BLUE WIRE ON THE
MOTOR IS THE COMMON WIRE AND IS ALWAYS TO THE “W” ON THE TERMINAL STRIP IN
THE CONTROL PANEL. THE BROWN AND BLACK WIRES ARE THE MOTOR DIRECTIONS AND
ARE CONNECTED TO “U+V” FOR MOTOR 1 OR “X+Y” FOR MOTOR 2.

ENSURE BOTH MOTORS ARE ADEQUATELY EARTHED.

U V W X Y E E3

U V W W X Y

MOTOR 1 MOTOR 2

MOTOR

EARTH

MOTOR

EARTH