1.2 - Basic Cable Layout

THIS DIAGRAM DETAILS THE BASIC CABLE LAYOUT FOR A PAIR OF MOTORS.

THE POWER SUPPLY TO THE CONTROL PANEL SHOULD BE LIVE AND PROTECTED IN
ACCORDANCE WITH THE 16TH EDITION ELECTRICAL REGULATIONS. THE SUPPLY SHOULD
BE RATED AT A MINIMUM OF 6 AMPS. WHEN INSTALLING WIRES OUTDOORS THE CABLE
APPROACH TO ALL DEVICES MUST BE FROM BELOW TO CREATE A “DRIP-LOOP” AND
THEREBY AVOID UNNECCESSARY WATER INGRESS.

1.3 - Low Voltage Cable Layout

THIS DIAGRAM DETAILS THE BASIC CABLE LAYOUT FOR A PAIR OF MOTORS.

THE POWER SUPPLY TO THE CONTROL PANEL SHOULD BE LIVE AND PROTECTED IN
ACCORDANCE WITH THE 16TH EDITION ELECTRICAL REGULATIONS. THE SUPPLY SHOULD
BE RATED AT A MINIMUM OF 6 AMPS. WHEN INSTALLING WIRES OUTDOORS THE CABLE
APPROACH TO ALL DEVICES MUST BE FROM BELOW TO CREATE A “DRIP-LOOP” AND
THEREBY AVOID UNNECCESSARY WATER INGRESS.

CONTROL PANEL

240V A.C.

JOINT BOX

3 CORE SWA 1.5mm

MOTOR CABLE

IN DUCTING

JOINT BOX

3 CORE SWA 1.5mm

FROG UNDERGROUND

CASING

8 CORE 0.2mm STRANDED TO

ALL SAFETY BEAMS

COAX CABLE

TUNED

ANTENNA

DOC E SAFETY