4 - troubleshooting guide, Problem, Solution – CAME Frog-AEP24 Kit User Manual

Page 20

Advertising
background image

4 - TROUBLESHOOTING GUIDE

A multimeter will be needed

PROBLEM

GATE WILL NOT RESPOND
WHEN GIVEN A COMMAND

GATES ARE OPEN BUT

WILL NOT CLOSE AND

GREEN LED IS FLASHING

WHEN COMMISSIONING GATE

AUTOMATICALLY OPENS BUT

DOES NOT AUTOMATICALLY

CLOSE

1.

CHECK POWER SUPPLY TO THE
CONTROL PANEL.

2. CHECK

CONTROL PANEL FUSES.

3.

CHECK HARD WIRE LINK FITTED
BETWEEN TERMINALS 1 & 2.

4. CHECK

THAT CAPACITORS

ARE

FITTED AND WIRED CORRECTLY.

1.

CHECK SAFETY BEAMS ARE WIRED
CORRECTLY. (IF MORE THAN ONE
SET OF BEAMS ARE FITTED THEY
MUST BE WIRED IN SERIES.)

2.

CHECK THAT THERE IS POWER
GOING TO THE BEAMS, IF NOT
RESTORE POWER.

3. IF

SAFETY BEAMS

ARE

NOT FITTED

ENSURE THAT A HARD WIRE LINK IS
FITTED BETWEEN TERMINALS 2 & C1

4.

REMOVE SAFETY BEAM WIRES 2 &
C1 FROM CONTROL PANEL AND
CHECK IF YOU HAVE A NORMALLY
CLOSED CIRCUIT COMING FROM
THE BEAMS.

1.

MOTOR WIRES ARE WRONG WAY
ROUND. CHECK AND PROVE MOTOR
DIRECTION BY MOMENTORIALLY
PULSING TERMINALS 2 & 3. THE
GATE SHOULD OPEN UP. TURN
AUTOMATIC CLOSING OFF (DIP
SWITCH 2) UNTIL MOTOR
DIRECTION HAS BEEN PROVED.

SOLUTION

19