4 - automatic close & activating safety photocells – CAME Frog-AEP24 Kit User Manual

Page 17

Advertising
background image

1.

TO SELECT AUTOMATIC CLOSING,
SELECT DIPSWITCH 2 ON.

SET THE AUTOMATIC CLOSING TIME BY ADJUSTING POTENTIOMETER TCA

FULLY ANTI-CLOCKWISE WILL APPROX. AUTOMATICALLY CLOSE THE GATES AFTER 10
SECONDS AND FULLY CLOCKWISE WILL APPROX. CLOSE THE GATES AFTER 80 SECONDS.
A SENSIBLE SETTING IS ABOUT HALWAY (I.E 6 O’CLOCK POSITION) WHICH WILL
AUTOMATICALLY CLOSE THE GATES AFTER APPROX. 30 SECONDS.

2.

FOR RE-OPENING DURING CLOSING.
REMOVE HARD WIRE LINK BETWEEN
2 & C1 AND INSERT SAFETY BEAM
WIRES AS SHOWN.

10 11 1 2 3 5 7 C1

10 11 C NC

3.4 - Automatic Close & Activating Safety Photocells

ON

OFF

1

1

TRIMMER TCA

6 O’CLOCK POSITION

16