2 - opening & closing the gates – CAME Frog-AEP24 Kit User Manual

Page 15

Advertising
background image

5.

SELECT DIPSWITCHES 1 & 2 OFF FOR
COMMISSIONING

6.

ENSURE HARD WIRE LINK IS FITTED
BETWEEN TERMINALS 1 & 2 AND
2 & C1

1.

MOMENTARILY PULSE TERMINALS
2 & 3 WITH A PIECE OF WIRE
TRAILING FROM TERMINAL 2 AND
MOMENTARILY TOUCHING
TERMINAL 3.

THE GATES SHOULD START TO
OPEN. IF THEY START TO CLOSE
TURN THE POWER OFF TO THE
CONTROL PANEL AND CHANGE
AROUND EITHER U-V (MOTOR 1) OR
X-Y (MOTOR 2) TO CHANGE
THE MOTOR DIRECTION.

2.

ONCE YOU HAVE PROVED THE
MOTOR DIRECTION USE
TERMINALS 2 & 7 TO OPEN AND
CLOSE THE GATES WITH A
TRAILING WIRE ONCE AGAIN INTO
TERMINAL 2, MOMENTARILY
TOUCHING TERMINAL 7.

ON

OFF

1 2 3

10 11 S 1 2 3 3P 4 5 7 2 C1 CX B1 B2

L1 L2 U V W X Y E1 10 11 1 2 3 5 7 C1

L1 L2 U V W X Y E1 10 11 1 2 3 5 7 C1

3.2 - Opening & Closing the Gates

14

Advertising
This manual is related to the following products: