3 - 3

An Eclipse-32 matrix requires 100 to 240 VAC at 50 to 60 Hz with a
maximum dissipation of 40W.

INTERCOM PANELS

V-Series Panels and Expansion Panels

Each V-Series panel or expansion panel has a separate external DC
power supply. The power supply is “universal”, operating over a
voltage range of 100 to 240 VAC at 50 to 60 Hz. The maximum
dissipation is 50W.

4000 Series II Panels and Expansion Panels

Each 4000 Series II panel or expansion panel has a separate external
DC power supply. The power supply is “universal”, operating over a
voltage range of 100 to 240 VAC at 50 to 60 Hz. The maximum
dissipation is 30W.

i-Series Intercom Panels

Each i-Station has an internal power supply, with a removable AC
power cord. The power supply is “universal”, operating over a voltage
range of 90 to 245 VAC and 50 to 60 Hz. The maximum dissipation is
40W.

ICS-2003 Intercom Panels

Each ICS-2003 intercom panel has a separate external DC power
supply. The power supply is “universal,” operating over a voltage range
of 90 to 260 VAC at 45 to 65 Hz. The maximum dissipation is 30W.

ICS-1008/ICS-1016 Intercom Panels

Each ICS-1008/ICS-1016 intercom panel has a separate external DC
power supply. The power supply is “universal”, operating over a
voltage range of 90 to 260 VAC at 45 to 65 Hz. The maximum
dissipation is 30W.

ICS-52/62/92/102 Intercom Panels

Each ICS-52/62/92/102 intercom panel is powered by a transformer
that runs off of AC mains power: the 120-V transformer requires a
two-conductor wall outlet, and is housed in a 2 x 2 x 3 in. (5 x 5 x 7.6
cm) direct plug-in module; the 240-V transformer requires a
three-conductor wall outlet, and is housed in a 2 x 3 x 5 in. (5 x 7.6 x
12.7 cm) box located in the middle of its cable’s length. Each
transformer connects to each compact panel with the 2.1 mm coaxial
power connector on the rear of the panel.

An ICS-102/92/62/52 intercom panel requires 90 to 125 or 210 to 250
VAC at 45 to 65 Hz with a maximum dissipation of 40W.