Imf-3 interface module frame wiring, Imf-102 interface module frame wiring, Imf-3 interface module frame wiring -23 – Clear-Com Eclipse-Omega User Manual

Page 53: Imf-102 interface module frame wiring -23

Advertising
background image

Clear-Com Communication Systems
Eclipse Matrix Installation Instruction Manual

4 - 2 3

calls directly to or from any intercom panel in an Eclipse or other
system. The TEL-14 interface has its own manual in the Eclipse
manual set. This following discussion gives an overview of the wiring
of this interface.

The TEL-14 uses each of the RJ-45 connectors on its rear panel for
connection to a matrix port. One RJ-45 is for Line A of the interface
and the other RJ-45 is for Line B of the interface.

The DB-9M connectors are the Line A and Line B connections to the
telephone line. Clear-Com provides DB-9F to RJ-11 adapters so that
standard phone line RJ-11 plugs and jacks can connect directly to the
interface.

IMF-3 Interface Module Frame Wiring

On the rear of the IMF-3 frame, there is a separate rear-panel
assembly for each interface, which contains four connectors for each
interface. The following instructions refer to any single rear-panel
assembly.

The upper DB-9M connector is used to connect to the first telephone
line, A. The upper RJ-45 connector is used to connect telephone line A
to the matrix frame. The lower DB-9M connector is used to connect to
the second telephone line, B. The lower RJ-45 connector is used to
connect telephone line B to the matrix frame. Figure 4-16 illustrates the
wiring of one IMF-3 rear-panel assembly to a TEL-14 interface.

Figure 4-16: Wiring an IMF-3 Rear-Panel Assembly to a TEL-14 Inter-

face

To allow use of a common RJ-11 terminated telephone line, Clear-Com
provides two DB-9F to RJ-11 adapters (Clear-Com part 770025).

For internal dip-switch settings and adjustments, refer to the TEL-14
manual (part 810308Z).

IMF-102 Interface Module Frame Wiring

On the rear of the IMF-102 frame, there are two sets of four connectors
each, arranged horizontally. The following instructions refer to either
one of the two sets.

CH. A

Matrix

CH. A

I/O

CH. B

Matrix

CH. B

I/O

PHONE

LINE A

PHONE

LINE B

Connects telephone line A to matrix.

Connects to the first telephone line, A.

Connects to second telephone line, B.

Connects telephone line B to matrix.

Advertising
This manual is related to the following products: