Wiring an ics panel accessory connector, Wiring an ics panel accessory connector -38, Figure 4-26 accessory panel connector pinout -38 – Clear-Com Eclipse-Omega User Manual

Page 68

Advertising
background image

Clear-Com Communication Systems

Eclipse Matrix Installation Instruction Manual

4 - 3 8

WIRING AN ICS PANEL ACCESSORY
CONNECTOR

An intercom panel can be connected to an accessory key panel via the
accessory panel connector. To connect an accessory panel use the
DB-9 connector cable supplied with the Accessory Panel. Connect the
cable between the panel and the input connector of the first accessory
panel. To connect a second panel use another DB-9 cable and connect
it between the output connector of the first panel to the input connector
of the second panel. Continue this process for as many accessory
panels as needed for each panel.

If a custom length cable is necessary, use a nine-conductor cable of at
least 24 AWG are larger wire and wire all pins one-to-one with a male
on one end and a female on the other. The distance between the
intercom panel and the last accessory panel should be no more than
25 feet (7.62 meters).

Figure 4-26: Accessory Panel Connector Pinout

Ground

1

2

9

8

7

6

5

4

3

Serial Clock Out

Reset (Strobe)

No Connect

Serial Data Out

+ Voltage Unregulated

+ Voltage Unregulated

Key Data In

Ground

Advertising