Specifications

Specifications are subject to change without notice.

Specification

Details

Ambient temperature

-5 to 50°C (23 to 122°F)

Storage temperature

-20 to 70°C (-4 to 158°F)

Operating humidity

0 to 95% non-condensing relative humidity

Operating altitude

From 0 to 2,000 m. (6,550 ft.) above sea level

EMC requirements

EN61326-1:2006 Directive 2004/108/EEC

Note: The wall mount instrument is a Class A product. In a domestic environment this
product may cause radio interference in which case the user may be required to take
adequate measures.

CE compliance

EN61010-1: 2010 Directive 2006/95/EEC

Safety rating

ETL, conforming to UL 61010-1 and CSA 22.2 No. 61010-1

Enclosure ratings

IP 65; Totally protected against dust; Protected against low pressure jets of
water from all directions.
NEMA 4X (wall mount only); Totally protected against dust; Protected against
pressure jets of water from all directions.

Power supply

Universal 100 VAC to 240 VAC @ 50/60Hz - 40VA; 10 to 30 VDC - 30W

Analog current output version
on the measurement board

4-20 mA (default) or 0-20 mA (configuration with software);
3 configurable outputs; Maximum load: 500 ohm; Sensitivity: 20μA;
Accuracy: ± 0.5% (between operating temperature limits)

Analog voltage output version
on the measurement board

0- 5 V output (hardware option);
3 configurable outputs; Minimum load: 10 KOhm; Sensitivity: 5 mV;
Accuracy: ± 0.5% (between operating temperature limits)

Measurement alarm relays on
the measurement board

Three alarm relays; 1A-30 VAC or 0.5A-50 VDC on a resistance load
Configurable to Normally Open [NO] or Normally Closed [NC] contacts by
changing the jumper positions

W A R N I N G

Potential Electrocution Hazard. Connect only safety low voltage < 33 VAC
RMS

System alarm relay on the main
board

One system alarm relay; 1A-30 VAC or 0.5A-50 VDC on a resistance load
Normally closed [NC] (NO relay also available) when instrument is turned on

W A R N I N G

Potential Electrocution Hazard. Connect only safety low voltage < 33 VAC
RMS

Thermal cut off

Prevents ageing of sensors when exposed to high temperatures

Options

RS-485 or PROFIBUS-DP (optional); USB client; USB host; Ethernet
10/100 Base-T

Wall and pipe mount instrument
(H x D x W)

236.5 x 160 x 250 mm - weight 3.8 kg
9.31 x 6.30 x 9.84 ins. - weight 8.38 lbs

Panel mount instrument
(housing) (H x D x W)

156 (123) x 250 x 220 (214) mm - weight 2.9 kg
6.14 (4.84) x 9.84 x 8.86 (8.43) ins. - weight 6.39 lbs

English 3