Modbus register – Hach-Lange NO3D sc Nitrate Sensor User Manual

Page 46

Advertising
background image

46

Modbus Register

NO3 CONC 1

40079

Float

2

R

0/2576

NO3 mV CONC 1

40081

Float

2

R

–250/400

NO3 mV drift

CONC 1

40083

Float

2

R

–500/500

CL- CONC 1

40085

Float

2

R

0/2000

CL- mV CONC 1

40087

Float

2

R

–300/400

CL- mV drift CONC 1

40089

Float

2

R

–500/500

TEMP CONC 1

40091

Float

2

R

0/45

DATE 2

40093

Time2

2

R

NO3 N CONC 2

40095

Float

2

R

0/2000

NO3 CONC 2

40097

Float

2

R

0/2576

NO3 mV CONC 2

40099

Float

2

R

–250/400

NO3 mV drift

CONC 2

40101

Float

2

R

–500/500

CL- CONC 2

40103

Float

2

R

0/2000

CL- mV CONC 2

40105

Float

2

R

–300/400

CL- mV drift CONC 2

40107

Float

2

R

–500/500

TEMP CONC 2

40109

Float

2

R

0/45

OFFSET BY

NITRATE

40111

Float

2

R

–70/50

SLOPE NITRATE

40113

Float

2

R

20/150

OFFSET BY

CHLORIDE

40115

Float

2

R

–150/50

SLOPE CHLORIDE

40117

Float

2

R

20/100

NO3NmV

40129

Float

2

R

–2500/2500

NitrateMeasmV

40131

Float

2

R

–5000/5000

Nitrate VDrift

40133

Float

2

R

–5000/5000

Drift in mg/L 5sec

Nitrate Noise

40135

Float

2

R

–100/500

Noise in 10 seconds

CL-mV

40137

Float

2

R

–5000/5000

Signal Cl-

ChlorideMeasmV

40139

Float

2

R

–5000/5000

Chloride Drift mg/L

40141

Float

2

R

–5000/5000

Drift in mg/L 5sec

Chloride Noise

40143

Float

2

R

–100/+500

Noise in 10 seconds

pHDmV

40145

Float

2

R

–5000/5000

Table 4 Sensor Modbus Register (continued)

Tag Name

Register #

Data Type

Length

R/W

Discrete

Range

Min/Max

Range

Description

Advertising