Appendix a modbus register – Hach-Lange SURFACE SCATTER 7 sc Turbidimeter User Manual

Page 59

Advertising
background image

57

Appendix A Modbus register

Tag Name

Register #

Data Type

Length

R/W

Description

TURB

40001

Float

2

R

Measured turbidity value

TURB INT

40003

Unsigned Integer

1

R

Integer turbidity value

TURB INT X 100

40004

Unsigned Integer

1

R

Integer turbidity * 100

SENSOR NAME

40005

String

6

R/W

Sensor name or location

BUBBLE REJECT

40011

1

1

In order to write to these tags, write 46478 to register 49938

Unsigned Integer

1

R/W

Bubble reject status (0=OFF; 1=ON)

SIGNAL AVG

40012

1

Unsigned Integer

1

R/W

Signal average (0=1; 1=6sec;
2=30sec;3=60sec;4=90sec)

DATALOG INTRVL

40013

1

Unsigned Integer

1

R/W

Datalog interval
(0=5sec;1=30sec;2=1min;3=2min;4=5min;6=10
min;7=15min;8=30min;9=60min, 10=4hr)

RESOLUTION

40014

Unsigned Integer

1

R/W

Maximum number of decimal places (0=xxxxx,
1=xxxx.x, 2=xxx.xx)

P/F CRITERIA

40015

1

Unsigned Integer

1

R/W

Pass / Fail criteria for verification. (1 to 10
percent)

TURB UNIT

40016

Unsigned Integer

1

R/W

Turb units (0=mg/L:7=NTU;42=FTU)

SERVICE MODE

40018

1

Unsigned Integer

1

R/W

Used to determine if the instrument is in the
service mode (0 = disabled; 1= enabled)

SERIAL NUMBER

40021

String

6

R

Instrument serial number

CODE VERSION

40027

Float

2

R

Software version

DD Firmware

40029

Unsigned Integer

1

R

Device driver firmware version

DD CONTENT

40030

Unsigned Integer

1

R

Device driver content version

HW VERSION

40031

Unsigned Integer

1

R

Hardware version of pc board

TEMP

40032

Float

2

R

Temperature measurement in Celsius

DARK

40034

Unsigned Integer

2

R

Dark turbidity A/D counts.

RAW TURB

40036

Float

2

R

Turbidity value with dark offset and
gain applied.

TURB COUNTS

40038

Unsigned Integer

2

R

Turbidity A/D counts

TEMP MAX

40040

Float

2

R

Maximum temperature

TEMP MIN

40042

Float

2

R

Minimum temperature

LAMP V

40044

Float

2

R

Lamp voltage

LAMP CURR

40046

Float

2

R

Lamp current (amps)

Plus 5V

40048

Float

2

R

Plus five volt measurement

INPUT V

40050

Float

2

R

Input voltage (~12V)

VREF

40052

Float

2

R

Voltage reference measurement (2.5V)

CAL GAIN

40067

Float

2

R

Calibration gain factor - used to convert A/D
counts to turbidity

INITIALS

40083

String

2

R

Initials used for the latest calibration

LAST CAL DATE

40085

Time2

2

R

Time of the latest calibration

CAL VALUE

40087

Float

2

R

The standard value used for the latest
calibration

Advertising