Sd controller, 4 english – Hach-Lange SD900 Refrigerated Sampler, SD900 AWRS Basic User Manual User Manual

Page 4

Advertising
background image

Specification

Refrigerated

AWRS

Sample bottle
capacity

Single bottle: 10 L (2.5 gal) glass or polyethylene, or 21 L (5.5 gal) polyethylene

Multiple bottles: two 10 L (2.5 gal) polyethylene and/or glass, four 10 L (2.5 gal)
polyethylene and/or glass, eight 2.3 L (0.6 gal) polyethylene and/or 1.9 L (0.5 gal) glass,
24 1 L (0.3 gal) polyethylene and/or 350 mL (12 oz.) glass

Warranty

1 year

1

Refer to the expanded version of this manual for a dimension drawing.

2

Radio frequency interference in the 30 to 50 MHz range can cause a maximum temperature change of 1.3 °C
(34.3 °F). Adjust the set point temperature to 2 to 10 °C (35.6 to 50 °F) to correct this interference.

SD controller

Specification

Details

Dimensions (W x H x D)

29.2 x 17.1 x 26.4 cm (11½ x 6¾ x 10

3

/

8

in.)

Weight

4.2 kg (9.26 lb)

Enclosure

PC/ABS blend, NEMA 4X, 6, IP 67

Power requirements

Refrigerated sampler: 15 VDC supplied by a 8754500 power supply; AWRS
sampler: 15 VDC supplied by an integral power supply

Overload protection

7 A, DC line fuse for the pump

Operating temperature

0 to 50 °C (32 to 122 °F)

Storage temperature

–30 to 60 °C (–22 to 140 °F)

Storage/operating humidity

100% condensing

Pump

Peristaltic high speed, with spring-mounted Nylatron rollers

Pump enclosure

IP37

Pump tubing

9.5 mm ID x 15.9 OD mm (

3

/

8

in. ID x

5

/

8

in. OD) silicone

Pump tubing life

20,000 sample cycles with: 1 L (0.3 gal) sample volume, 1 rinse, 6 minute
pacing interval, 4.9 m (16 ft) of

3

/

8

in. intake tube, 4.6 m (15 ft) of vertical lift,

21 °C (70 °F) sample temperature

Vertical sample lift

Maximum 8.5 m (28 ft) for: 8.8 m (29 ft) of

3

/

8

-in. vinyl intake tube at sea level

at 20–25 °C (68–77 °F)

Pump flow rate

4.8 L/min (1.25 gpm) at 1 m (3 ft) vertical lift with

3

/

8

-in. intake tube typical

Sample volume

Programmable in 10-mL (0.34 oz) increments from 10 to 10,000 mL (3.38 oz to
2.6 gal)

Sample volume repeatability
(typical)

±5% of 200 mL sample volume using uncalibrated liquid detect with: 4.6 m
(15 ft) vertical lift, 4.9 m (16 ft) of

3

/

8

-in. vinyl intake tube, single bottle, full

bottle shut-off at room temperature and 1524 m (5000 ft) elevation

Sample volume accuracy
(typical)

±10% of 200 mL sample volume using uncalibrated liquid detect with: 4.6 m
(15 ft) vertical lift, 4.9 m (16 ft) of

3

/

8

-in. vinyl intake tube, single bottle, full

bottle shut-off at room temperature and 1524 m (5000 ft) elevation

Sampling modes

Pacing: Time-fixed, flow-fixed, time-variable, flow-variable, constant time
variable volume (CTVV).
Refer to Constant Time Variable Volume (CTVV) sampling in the expanded
version of this manual.
Distribution: Single bottle composite, multi-bottle composite, multi-bottle
discrete, bottles per sample, samples per bottle, combination of bottles per
sample, samples per bottle

Run modes

Continuous or non-continuous with user-entered number of samples

4 English