Variable script_input_reset, Ariable script_input_reset – CognitiveTPG DLXi User Manual

Page 255

Advertising
background image

P R I N T E R S E T U P

VARIABLE SCRIPT_INPUT_RESET

Function

This command will cause the input source to be

reset when the user enters the menu level specified.

Explicit Form

Implicit Form

VARIABLE SCRIPT_INPUT_RESET n

V SCRIPT_INPUT_RESET n

Parameters

n

The numbers of menus to execute before

looking for data from a different source.
Allowable values are 0 to 100 with a default

value of 0.

Comments

When using this command, send it to the printer
with VARIABLE WRITE in a non-printing label

format. Do not use this command in stored label
formats

Example

The following will cause the printer to look for input
from all possible sources after executing the first

menu.

! 0 0 0 0

VARIABLE SCRIPT_INPUT_RESET 1

VARIABLE WRITE

END

246

Revision F, January 2012, CognitiveTPG