T R O U B L E S H O O T I N G

Numeric values do not increment properly in response to the

ADJUST command.

Cause: The numeric value you wish to adjust has more digits than

the parameter specified in the

ADJUST

command.

• Cure: Pad the

ADJUST

parameter with leading zeros as

required.

Cause: You are trying to adjust a numeric value to a number with

more digits than the original value.

• Cure: Pad the original value with leading zeros as required.

Cause: You are using a

MULTIPLE

command with

ADJUST

.

• Cure: This is acceptable, but remember:

ADJUST

will only

increment the adjusted numeric value when the printer feeds a

label. Duplicate labels printed side-by-side will always be identical.

Cause: You are trying to increment numeric data that does not

appear at the end of a command line.

• Cure: This may be acceptable, but the

ADJUST

command can

only increment numeric data. If alpha characters follow the
numeric data, you must follow the

ADJUST

parameter with enough

zeros to pad the increment value away from the alpha characters.

Bar code or string positioning is incorrect.

Cause: A required space was left out or an extra space was inserted
somewhere in the

BARCODE

or

STRING

command, causing the printer

to interpret the parameters incorrectly.

• Cure: Use blank spaces as shown in the command descriptions.

Ultra Font or TEXT font positioning is incorrect.

Cause: The label format has a

JUSTIFY

command in it that you have

not accounted for.