Controlled Products Systems Group 7200ETL-IL User Manual

Page 15

Advertising
background image

15

Board

Actuator

Function

Cable

Pin 1

Orange

Open Limit

Pin 2

White

Close Limit

Pin 3

Black

Motor (positive on open, negative on close)

Pin 4

Red

Motor (negative on open, positive on close)

Pin 5

Green

Common for both limit switches

Pin 6

Yellow

Feedback from intelligent actuator(816E/816EX)

Pin 7

Black

Battery Negative

Pin 8

Red

Battery Positive

1

3

5

7

2

4

6

8

Actuator Connector

Applies battery voltage directly to motor to open gate if
control board fails. User must unplug before gate opens
to maximum travel or 15 amp fuse will open. Fuse
should be checked before returning gate to service.

EMERGENCY BYPASS (open only)

Photo eye / safety loop wiring. Connect the positive power wire of the accessory to
12V. Connect the ground wire of the accessory to MAS (upper right area of the
835/836 board). Connect the relay wires of the accessory as normal: COM to GND.
NO to SAFETY (#14) (for a safety device). When the gate operator begins opening
(comes off of the closed limits) the MAS terminal will become a ground and will
complete the flow of power to the accessory. This will power the accessory up and it
will work as normal until the gate gets closed and the MAS terminal switches and the
device will power down.

Photo Eye Hookup

12V

Supplied battery voltage

MAS

Master Operator Indicator (indicates master side of gate is closed)
+12V when on closed limit. Ground when off of closed limit.

SLV

Slave Operator Indicator (indicates slave side of gate is closed)
+12V when on closed limit. Ground when off of closed limit.

GND

Battery supplied ground

SIREN

Connect to siren +
applies +12V when gate(s) are running, or in hard shutdown

GND

Battery supplied ground

LOCK

Connect to lock + (optional) Magnetic or Solenoid type locks (Dip Switch #6 Selectable)

Remote Outputs and Photo Eye Hookup