Adjustments push buttons, Jumpers – Controlled Products Systems Group 7200ETL-IL User Manual

Page 16

Advertising
background image

16

Adjustments

Push Buttons

TIMER TO CLOSE

Adjusts time before gate automatically closes
Adjustable 5 to 70 seconds.

DUAL GATE DELAY

Adjusts delay between master and slave op-
eration 0-4 seconds (836 only for use with
magnetic, solenoid, and other locking de
vices)

CURRENT SENSITIVITY Increases or decreases the Auto Reverse

sensitivity.

LED ENABLE When depressed, activates LEDs for 15

minutes to assist in installation and troubleshooting.

Hold the push button down for five seconds to put
the board in program mode.

RESET

Resets the microprocessor. Returns processor to
last known state.

OPERATE

When depressed, activates the gate. Used for initial
installation and testing.

Hard Shutdown Reset Resets the operator when the gate current

senses twice before fully opening or closing.

Jumpers

STOP CIRCUIT JUMPER

When the STOP CIRCUIT

program switch #5 must be ON

JUMPER is connected, the gate
will operate normally.

STOP CIRCUIT JUMPER

When a 3-button station is con-

program switch #5 must be OFF

nected to the board, the STOP
CIRCUIT JUMPER must be re-
moved.