GND

Supplied Battery Ground

INP

Activate Gate (Push button activation when momentarily shorted to ground)

12V

Supplied Battery Voltage (Protected with 3 Amp fuse)

GND

Supplied Battery Ground

INP

Activate Gate (Push button activation when momentarily shorted to ground)

12V

Supplied Battery Voltage (Protected with 3 Amp fuse)

EDGE

Reverse edge input. When grounded, will stop and reverse gate if closing, resets close timer if gate is open.

EDGE

Reverse edge input. When grounded, will stop and reverse gate if closing, resets close timer if gate is open.

GND

Supplied Battery Ground

GND

Supplied Battery Ground

STOP

Stop input from a 3 button station (must remove STOP CIRCUIT JUMPER) Normally closed

CLOSE Close input from a 3 button station (see program switch #5 for options)

OPEN

Open input from a 3 button station (see program switch #5 for options)

GND

Supplied Battery Ground

GND

Supplied Battery Ground

FREE EXIT Opens gate if closed, stops and reverses gate if closing, resets close timer if gate is open.

GND

Supplied Battery Ground

SHADOW Resets close timer when gate is open (also referred to as under gate loop)

GND

Supplied Battery Ground

SAFETY Resets close timer if gate is open, stops and reverses if gate is closing. (Does not open a closed gate)

GND

Supplied Battery Ground

FIRE

When grounded, opens gate and holds gate open until released.
Clears “Hard Shutdown” mode of software.

UL

When grounded, opens gate and holds gate open until released.
Clears “Hard Shutdown” mode of software.

Optional Device Inputs

GND

Supplied Battery Ground

INP

Activate Gate (Push button activation when momentarily shorted to ground)

12V

Supplied Battery Voltage (Protected with 3 Amp fuse)