Tools required

• You will need the following tools:

• Rubber mallet
• Thread Sealant
• Adjustable wrench
• Needle-nose pliers
• Flat-end screwdriver
• Lubriplate™ lubricant (08465)
• Scribe set (08126)
• Pro Gun™ Oil (04394)
• Seal Installation tool (58198-1)
• HV Pro Gun™ packing bit (58199-1)
• Catalyst Alignment Tool (6705-3-1)

• You should also have appropriate cleaning materials such as solvent, clean shop

towels or rags, a small brush, and empty containers into which you will flush the gun.

• Also, you will need new o-rings and seals to replace the current ones in the HV

Pro Gun™. Please refer to the parts drawings to obtain proper parts numbers for
the o-rings and seals to be replaced.


Note: If you are using o-ring part number O-K-008 in the flush assembly, you do
not need to replace the o-ring unless it is showing obvious signs of wear. This o-
ring is specially designed to handle most solvents
.

DANGER: To prevent accidental injection injury, disconnect all air and electrical
power to the unit before beginning repair or maintenance on this equipment.

Release Pressure

1.

Turn off air supply to pumping system.

2.

Release fluid pressure from lines by holding the gun over an appropriate empty
container and pulling the trigger.

3.

Flush gun into appropriate container

4.

Turn off air supply to the solvent tank.

5.

Release any pressure in the flush tank by gently pulling upwards on the ring
attached to the pressure relief valve.

6.

Place an empty container under the ball valve located at the bottom of the filter
assembly.