Magnum Venus Plastech High Volume Pro Gun 60625-1 User Manual

Page 17

Advertising
background image

High Volume Pro Gun Manual

Rev. 05/2012

Page | 17

7.

SLOWLY open the ball valve, you can leave the ball valve open or close it when
the all the pressure has been released.

8.

Open the dump / recirculation valve located on the catalyst manifold, if
appropriate.


Disable Catalyst Pump

Slave Arm pumps

1.

Remove the quick pin from the top of the catalyst pump and upper slave arm.


2.

Tilt the catalyst pump away from the resin pump until the catalyst pump is
resting against the vertical connecting post.


3.

Trap the catalyst pump’s upper bearing block between the vertical connecting
post and the quick pin.


UPS

1.

Remove the hairpin from the quick pin assembly.


2.

Remove the quick pin assembly from the pivot link assembly

Remove Hoses

Note: Although previous steps should have removed all pressure from the lines,
there may still be trapped fluids under pressure in the lines. Read the
recommended safety procedures below.

WARNING: Wear appropriate eye protection. Pressurized fluids may cause eye
injuries.

WARNING: When removing hoses from fittings, wrap a large rag or shop towel
around the wrench and fitting as you remove the fitting. Remove fitting slowly to
allow any pressurized fluid to escape into the rag or towel.

1.

Wrap a large rag or shop towel around the resin fitting and a wrench.


2.

Use the wrench to loosen the fitting slowly until you can remove the resin hose
from the fitting.


3.

Use this technique to remove the solvent hose, and the catalyst hose.


Advertising
This manual is related to the following products: