FLUSH BODY

PUSH STEM

O-RING

BACK-UP RING

GRIP RING

SPRING

FLUSH VALVE BODY

HOSE CLAMP

BARBED FITTING

SEAL

9.

Install the spring and push stem into the flush body.

10. Install a new o-ring onto the end of the push stem sticking out of the flush body.

11. Install the back-up ring onto the end of the push stem against the new o-ring.

12. Install the grip ring onto the end of the push stem.

13. Thread the auto/manual flush body assembly into the flush valve body.

14. Screw the flush valve assembly (5104-01-01) into the front side port on the resin

side of the gun block


Note: If using o-ring part number O-K-008 (o-ring is used on the flush button),
you do not need to replace the o-ring unless it is showing obvious signs of wear
or damage. This o-ring is specially designed for use with all solvents.

Note: In some cases O-K-008 o-ring can be replaced with the more economical o-
ring (O-E-008).