Note: For systems without Auto/Manual flush assemblies skip steps 9 - 13
FLUSH BODY
PUSH STEM
O-RING
BACK-UP RING
GRIP RING
SPRING
FLUSH VALVE BODY
HOSE CLAMP
BARBED FITTING
SEAL
9.
Install the spring and push stem into the flush body.
10. Install a new o-ring onto the end of the push stem sticking out of the flush body.
11. Install the back-up ring onto the end of the push stem against the new o-ring.
12. Install the grip ring onto the end of the push stem.
13. Thread the auto/manual flush body assembly into the flush valve body.
14. Screw the flush valve assembly (5104-01-01) into the front side port on the resin
side of the gun block
Note: If using o-ring part number O-K-008 (o-ring is used on the flush button),
you do not need to replace the o-ring unless it is showing obvious signs of wear
or damage. This o-ring is specially designed for use with all solvents.
Note: In some cases O-K-008 o-ring can be replaced with the more economical o-
ring (O-E-008).