3.

Remove the flush valve body from the flush valve neck.


4.

Remove the flush valve seal from the flush valve body.


Note: For systems without Auto/Manual flush assemblies skip steps 5 - 7

FLUSH BODY

PUSH STEM

O-RING

BACK-UP RING

GRIP RING

SPRING

FLUSH VALVE BODY

HOSE CLAMP

BARBED FITTING

SEAL

5.

Unscrew the auto/manual flush body assembly from the flush valve body.

6.

Remove the grip ring from the push stem of the auto/manual flush body assembly.
Use caution not to lose the spring in the flush body.

7.

Remove the back-up ring and o-ring from the push stem.


8.

Unscrew the flush seal body (5104-23-1) from the flush valve button (5104-25-01).


9.

Remove the spring (9203-2-3).