53IT5100B Indicator/Totalizer

INSTRUCTION MANUAL

55

Protocol

The Datalink protocol requires the host to initiate all transactions. There are two basic categories for all of the
Datalink message types: Interrogate - used to read data from an addressed instrument, and Change used to
alter a value in an addressed instrument. The addressed instrument decodes the message and provides an
appropriate response. The protocol definitions for the Datalink message types are provided in Table B-2.

Table B-2. Message Field Definitions

Symbol

Title

Definition

SOH

Start of Header

This character, 7E, denotes the beginning of a message.

I.A.

Instrument Address

The address of the instrument responding to the transaction. It must
be within a range of 00-1F (00-31 decimal).

CMD

Command

Is the operation to be performed or a description of the message that
follows the Command-I.A. byte. The Command-I.A. byte has two
fields: the Command field (3 bits), and the I.A. field (5 bits). There
are five commands, listed as follows: Interrogate Change Change
Bits Acknowledge Response The commands are covered in Section
B.1.3, Message Types.

NUM

Number

The number of data bytes transferred or requested. The NUM must
be in a range of 00-32.

LO-ADD

Lower Address Bits

The least significant 8 bits of a 16 bit instrument address.

HI-ADD

Higher Address Bits

The most significant 8 bits of a 16 bit instrument address.

DATA

An 8 bit data byte.

XXXX

Represents a variable number of data bytes.

MASK

An 8 bit byte where each bit, called a flag, is dedicated to an event
that is permitted or prohibited, depending on the flag setting. If the
flag is set to 0, the event is permitted. If the flag is set to 1, the event
is prohibited.

STATE

Represents the bit settings of a particular byte: which bits are set to
1, and which bits are set to 0.

LRC

Longitudinal
Redundancy
Character

Is a character written at the end of the message that represents the
byte content of the message and is checked to ensure data was not
lost in transmission. It is the sum of all bytes Modulo 256 of the
message not including the SOH character or its own bit settings
(LRC).

Message Types

The types of messages that are sent between the host and the Datalink network instrument are formatted as
follows:

HOST TO INSTRUMENT:

1. INTERROGATE - This message requests up to 20H consecutively stored bytes, beginning at the

specified memory address location of the addressed instrument.

01111110 E0H + I.A. NUM LO ADD HI ADD LRC

2. CHANGE - This message sends up to 20H bytes of new data to the addressed instrument.

01111110 A0H + I.A. NUM LO ADD HI ADD Data 1 XXXXXXXXX Data N LRC

3. CHANGE BITS - This message alters only the specified bits in the specified bytes in the addressed

instrument. (NUM = 2n)

01111110 C0H + I.A. NUM LO ADD HI ADD Mask 1 State 1 XXXX Mask N State N LRC

Advertising