Micromod Micro-DCI: 53IT5100B Micro-DCI 4-Channel Indicator Totalizer User Manual

Page 60

Advertising
background image

53IT5100B Indicator/Totalizer

INSTRUCTION MANUAL

4. ACKNOWLEDGE - This message signals the addressed instrument that its last echoed change

message was received correctly; the instrument performs the change requested.

01111110 80H + I.A.

INSTRUMENT TO HOST:

1. RESPONSE - This message furnishes the data requested by the INTERROGATE command of the

Host. It is also used to echo back the previous CHANGE message of the Host.

01111110 20H + I.A. NUM LO ADD HI ADD Data 1 XXXXX Data N LRC

Communication Transaction Examples

Transaction A Example - Host requests 9 bytes of data beginning at hexadecimal memory address 1000H
from the instrument at Datalink address 03.

1. Host

sends

INTERROGATE message.

01111110 11100011 00001001 00000000 00010000 11111100

SOH

Command

+ I.A.

NUM

LO ADD

HI ADD

LRC


2. Instrument

sends

RESPONSE message.

01111110 00100011 00001001 00000000

0001000

0

XXXXX XXXXX XXXXX LRC

SOH

Command

+ I.A.

NUM

LO ADD

HI ADD

Data 1

.................

Data 9

Transaction B Example - Host or SUPERVISOR-PC sends two bytes of new data, to be loaded into the
instrument at Datalink address 03 beginning at hexadecimal memory address 1000H.

1. Host

sends

CHANGE message.

01111110 10100011 00000010 00000000

0001000

0

0000100

0

00001100

1100100

1

SOH

Command

+ I.A.

NUM

LO ADD

HI ADD

Data 1

Data 2

LRC

2. Instrument

sends

RESPONSE message.

01111110 00100011 00000010 00000000

0001000

0

0000100

0

00001100

0100100

1

SOH

Command

+ I.A.

NUM

LO ADD

HI ADD

Data 1

Data 2

LRC


3. Host

sends

ACKNOWLEDGE message.

01111110 10000011

SOH Command

56