13.1 Accessing the Setup Menu

To access the Setup Menu, ensure that the pump is OFF and in the

Internal mode. Using the

(Up) key, bring the stroke rate to 100

SPM. At this point, keep the

(Up) key pressed for five (5)

seconds. The LCD screen then displays the current software

revision, indicating that you have entered the Menu mode

.

Press the

I

N

T

T

MODE

E
X

(Mode) key to scroll through the Menu Items. Use

the

(Up) or

(Down) key to enable or disable menu

functions and program values.

To exit the Menu mode, press the

START

STOP

(Start/Stop) key. Or, if no

keys are pressed for 13 seconds, the display reverts to

MIN

INT

.

13.2 Menu Items

13.2.1 Menu Item 1: Batch Accumulate Enable/Disable

Batch Accumulate may be enabled (1)

or disabled (0)

. Use the

(Up) or

(Down) key to change the

selection.