Appendix A: Input/Output Description

4-Pin Connector

Pacing (Pulse) Input / Opto-Isolated Input (HH7 and HH9 Only)

Methods of Triggering Pump.

Reference: 4-Pin Cable (P/N 33796) (HH9 Only)

4-Pin Cable (P/N 28368) (HH7 Only)

Pin 1

Pin 2

Black

Black

Black

Black

White

White

White

White

Pin 1

Pin 2

+

-

Pin 1

Pin 2

+

-

Pin 1

Pin 2

+

-

NPN Transistor

Switch

PNP Transistor

Opto Isolator

HH9 Only
Switch or transistor must be capable of switching 2mA at
15 VDC. When in the Divide mode, the switch must close then
open to trigger.
Minimum time in low impedance state (i.e. switch closed) is
60 mSec. by default.
Setup Menu Item 6 sets this value in multiples of 4mSec.
Example: Default = 4 X 15 = 60 mSec