Hh xxx-987, 0 how to interpret the model number – Nova-Tech LMI Series HH Metering Pump User Manual

Page 7

Advertising
background image

7

Included on the data plate is the model number of the pump. Each
number in the model number represents the following in Figure 3b.

HH XXX-987

Figure 3a : Data Plate

Liquid End

Output Codes

Series
or Model

Cord & Voltage Codes

1 = 120 V US plug, UL
2 = 240 V US plug, UL
3 = 230 V DIN plug, CE
5 = 240 V UK plug, CE
6 = 250 V Aust/ NZ plug
7 = 230 V Swiss plug
8 = 120 V No plug, CE

Figure 3b : Model Number Representation

1 = 0.14 GPH at 300 PSI
2 = 0.10 GPH at 600 PSI
3 = 0.07 GPH at 1000 PSI

4.0 How to Interpret the Model Number

The silver data plate (located on the front of the pump) tells you how
your pump is configured.

115 V.A.C.

1.4 A

MODEL # HH931-987

SERIAL #

MAX/
GPH

0.07

PSI

1000

Control Code

1 = Manual
7 = Instrument

Responsive Manual

9 = Microprocessor/

Instrument
Responsive

50/60 HZ.

Advertising