Maintenance, Important – Poweramp VS SERIES HYDRAULIC User Manual

Page 27

Advertising
background image

25

4111-0008 — Sept 2012

MAINTENANCE

M — Reservoir
N — 2 in. (51 mm) (From Top of

Reservoir)

P — Breather Cap
Q — Fluid Level

• Check reservoir fluid level (Q):

1. The leveler must be in the stored position with

the lip lowered.

2. Turn OFF all electrical power to the leveler.

3. Remove breather cap (P).

4. Measure fluid level. The fluid level should be

approximately 2 in. (51 mm) (N) from top of
reservoir (M) with platform stored and the lip in
the flooded position.

5. Add hydraulic fluid if necessary. Use only

recommended fluid. (Pg 23)

6. Install breather cap

7. Turn ON electrical power to the leveler.

8. Return the lip to the raised position.

IMPORTANT

A low fluid level or the use of hydraulic fluids not
equivalent to the fluid types recommended, will
cause abnormal operation of the leveler and WILL
void warranty.

Checking Fluid Levels Reservoir on
Remote Pumps

M

Q

P

N

Pressure

Return

Advertising