Adjustments, Adjust main pressure relief remote mount – Poweramp VS SERIES HYDRAULIC User Manual

Page 29

Advertising
background image

27

4111-0008 — Sept 2012

ADJUSTMENTS

To adjust the main pressure relief:

1. The leveler must be in the stored position and the

maintenance prop in the service position.

2. Turn OFF all electrical power to the dock leveler.

Attach safety lockout and tagout devices.

3. Remove acorn nut (F).

4. Loosen jam nut (E).

5. Adjust allen head adjusting screw (D) as follows:

• Turn clockwise to increase pressure relief.

• Turn counterclockwise to decrease pressure

relief.

6. While holding the adjusting screw tighten jam nut

and install the acorn nut.

7. Turn ON electrical power to the dock leveler.

8. Check leveler operation.

9. Repeat steps 1– 9 as necessary.

A— Reservoir
B— Main Pressure Relief
C— Pump/Motor

D—Hex Adjusting Screw
E— Jam Nut
F— Acorn Nut

Adjust Main Pressure Relief Remote Mount

NOTE: The main pressure relief may need to be

increased if the platform does not rise or
rises slowly
and the system operates in
pressure relief mode. See Troubleshooting
section.

The main pressure relief may need to be

decreased if the pump motor loads down
when platform starts to raise from the
lowered position. See Troubleshooting
section.

When service under the dock leveler is required,
always lock all electrical disconnects in the OFF
position after raising the platform and engaging the
maintenance prop. Failure to do this may result in
serious personal injury or death.

Always post safety warnings and barricade the
work area at dock level and ground level to prevent
unauthorized use of the dock leveler before
maintenance is complete. Failure to do this may
result in serious personal injury or death.

A

D

E

F

C

B

Advertising