Load default data protocols, Load the default com settings – Fairbanks FB3000 II Operators Manual User Manual
Page 19

Section 4: Input/Output (I/O)
02/10
19
51220 Rev. 1
4.2.4. Load Default Data Protocols
When programming a Output Data String, the Fairbanks’ FB3000 II has five of the
most commonly used pre-configurations, known as
Load Defaults
. These data
strings are listed below:
Fairbanks
<STX><A><B><C><GGGGGG><TTTTTT><CR>
Toledo
<STX><A><B><C><GGGGGG><TTTTTT><CR>
Cardinal
<CR><P><WWWWWW><m><SP><U><SP><g><SP><SP><ETX>
Weightronix
< ><M><WWWWWW>< ><U><CR><LF>
Condec
<STX><P><WWWWWWW><U><G><M><CR>
4.2.5. Load the Default COM Settings
Follow these steps to configure the
Load Default
into the Output Data String.
3. From the Weighing Application
Window, press the
MENU
button,
from the Kernel Options Menu, select
Configuration Menu
.
4. Select
Configure Output.
.