Configure output, continued, Increment size, Status code (word) b – Fairbanks FB3000 II Operators Manual User Manual
Page 53: Status code (word) c
Advertising

Appendix III: Data Output
02/10
53
51220 Rev. 1
CONFIGURE OUTPUT, CONTINUED
Increment Size
Bit #
Count By 1
Count by 2
Count by 5
3
1 0 1
4
0
1
1
5
Always Logic 1
6
Always Logic 0
7
Parity Bit
Status Code (Word) B
Status Code (Word) C
Bit #
Description
0
Gross = 0
Net = 1
1
Positive = 0
Negative = 1
2
In Range = 0
Overcapacity = 1
3
No Motion = 0
Motion = 1
4
Lb = 0
Kg = 1
5
Always Logic 1
6
Normal = 0
Power Up = 1
7
Parity Bit
Bit #
Description
0
Always Logic = 0
1
Always Logic = 0
2
Always Logic = 0
3
Normal = 0
Print Switch Pushed = 1
4
Always Logic = 0
5
Always Logic = 0
6
Normal = 0
Keyboard Tare = 1
7
Parity Bit
Advertising