4.2.9. Other Data String Customization

Window Name

Description

CONFIGURE OUTPUT

Settings Tab

RS232 COM Port Drop-down

– Selects COM Port with its settings.

Data Transmission Options*

Continuous

[transmission]

Demand

– Upon demand as a poll character is received

Auto

– A transmission is sent when requested or when the

transaction is completed.

To File

– The message is not transmitted, but written to a file instead.

Network

– Transmission via IP over a network.

Port Settings*

Baud Rate, Parity, Data Bits

and

Stop Bits.

Checksum

– Returns a confirmation of transmission message

between computers.

Delimited

– Transmits data in Comma Delimited Format.

Multicast

– Method of networking scale weight information to other

FB3000 II instruments across a Network.

Map View

– Displays data in a memory mapped location.

ƒ

The

Testapp.exe

,

located in th

e

Kernel folder

, is used to verify

memory mapped data,

Output to PC104

– Sends data to optional PC 104 Weight Controller

Card using the

20mA or 4-20mA outputs.

Software Hand Shaking

A means to control data flow using software

functions for communication between two or more devices.

None

Bits are sent to source computer constantly without waiting for

available receiving modem.

Both, Receive or Transmit

– Determines which computer(s) wait

to accept the message packets.