Fairbanks LoadTronic 3 - Loader Weighing System User Manual
Page 13

OPERATOR’S MANUAL
page 13
Note: If the bucket is not fully tilted rearward, the message:‘BUCKET’
will be shown in place of the bucket weight (no weighing performed).
Comments:
x
When weighing begins, the Load-field starts to flash, and the value is
updated.
x
Weighing is completed when the weight of the current load is added to the
running total. The buzzer will give a sound signal if activated in
Parameter Setup II, refer Figure 3-6 and LOADTRONIC 3 Installation
Guide.
x
The total weight and the rest weight to be loaded will be updated.
x
The weight of the last bucket remains displayed until the load has been
dumped.
x
Press Print/F2 to clear the job and print a receipt (if a printer has been
installed), or press C/F1 to clear the job (no report).
Figure 3-2 Operator’s display during automatic weighing.
Number of buckets
Number of active
jobs
Time until next zero
adjustment