Load cell cables – Fairbanks VSX SERIES TRUCK SCALE User Manual
Page 24
 
Section 2: Installation
04/12
24
51173 Rev. 8
LOAD CELL CABLES
1. Cable protection on truck scales is extremely important to the reliability of the
scale. It is imperative for all cables to be installed off of the ground and securely 
fasten. The Tracker series scale has been designed to accommodate this type 
of cable protection. This section describes the manufacturer’s recommended 
installation procedure for installing and protecting cables on the Tracker series 
truck scale. 
2. Cable Hangers are beside every Smart Sectional Controller (SSC) or Pit Power
Supply (PPS) mounting block. These cable hangers are used to wrap excess 
load cell and interconnecting cables. 
3. Route the load cell cable through the angle under the crossbeam and through the
large hole in the bottom flange of the main girder beam directly underneath the 
cable hangers. 
Figure 2-10