Fairbanks VSX SERIES TRUCK SCALE User Manual
Page 30
 
Section 3: Wiring
04/12
30
51173 Rev. 8
Installing Load Cells, Continued
10. Set the Switches.
Dip (Address) Switch Setup, Smart Sectional Controllers (SSC)
 In each of the smart SSC boxes there is a 10-position dip switch labeled
S1
.
 This switch is used to identify the section in a binary code. 
 The switches must be set properly for the scale to operate. 
Note:
Switches 1, 2, and 3 are
always OFF.
Switch 5 ON = 700/1000 ohm load cells 
 
OFF = 350 ohm load cells
 Switches 6 thru 10 are used to set the section (section address) numbers.
11. Set the section number according to the following chart.
Section Number
6
7
8
9
10
Section 1
On
Off
Off
Off
Off
Section 2
Off
On
Off
Off
Off
Section 3
On
On
Off
Off
Off
Section 4
Off
Off
On
Off
Off
Switch Settings
12. Continue in this manner until each Smart Sectional Controller (SSC) box has a
unique section number entered on the dip switches.