Replacing an rc load cell, General load cell information, W a r ning – Fairbanks Trident Precast Concrete Deck Truck Scale User Manual

Page 33: Lift panels with a fork lift

Advertising
background image

Section 6: Parts

04/11

33

51255 Rev. 2

Replacing an RC load cell

1. Remove power from the instrument.
2. Lift the scale using a proper sized and rated hydraulic jack (or jacks) at the

corners closest to the defective load cell location

* * W A R NING * *

Place hydraulic jacks ONLY at the CORNERS of the modules.

Hydraulic jacks must be placed on opposite sides to lift the module in a level

position. Lifting mid-span or between load cells will cause cracks in the concrete!

3. Check upper and lower receiving cups and “O” rings for damage. Replace as

necessary and reapply grease.

4. Insert the new cell into the upper receiving cup and position the anti-rotation pin.
5. Carefully lower the hydraulic jack(s) until the cell is set into the lower cup.
6. Remove the cover of the SSC/J-box, then loosen the gland bushing to free the

cable. Remove the old cell wires and connect new cell wires in the balance

box/SSC. Secure the cover.

7. Test and adjust the scale as necessary.

General load cell information

Load cell part number: 70510

Description: 5½” – 2mV/V, 66k or 30t, 1000 Ω

Do

NOT

lift panels with a fork lift!

Advertising