INTRODUCTION

This manual provides installation instructions for the Fairbanks Trident Precast

Concrete Deck Truck Scale.

For complete Trident scale installation, use:

• Methods and Procedures FF-2267 / 101732 (Appendix I)

• The certified prints/setting plans supplied with the scale

• This installation manual, 51255

The concrete foundation work must be performed according to the certified prints

issued for the specific customer and order number. (The name and order number

for the particular customer will be on the prints.)

NOTE:

It is the owner's responsibility to document, notify, and follow-up regarding

shipping damage with the carrier.

DESCRIPTION

The factory poured truck scales are available in various lengths and widths. The

scale is made up of modules of 10', 15', 20' or 23'4" in length. All modules are

assembled and welded at the factory. The concrete deck is mixed, poured, placed,

finished, and cured at the factory.

The scale should be located so that vehicles can approach and exit the scale as easily

as possible. The platform should be visible from the instrument location. Drainage of

surface water must be such that water does not collect under the scale. Smooth and

level approaches are required at each end of the platform to reduce loading shock

and facilitate testing of the scale. Approaches must conform to the requirements of

the law in the state in which the scale is being installed. In the absence of such laws

the approaches must conform to paragraph UR.2.6 National Institute of Standards

and Technology Handbook 44, which states that the first 10 feet must be level and

on the same plane as the scale platform.

NOTE:

Specifications and sizes are shown in

Appendix II

.

CERTIFICATIONS

NTEP CC: 96-089A3

MC: AM - 4949

Advertising