3 . To reinstall the original drive or a new drive, follow the in-

structions from Section I – Assembly, Pumps without Motors,

Steps 4 - 6 .

Thrust Ring Replacement

1 . Thrust ring (item 3A) is held in-place with a press fit . Using

fingers, pliers or flat head screwdriver pry ring up and out of

the holder . See figure 24 .

2 . To reinstall simply press the thrust ring into the impeller by

hand . See figure 25 .

Figure 24

Figure 25

Bushing Replacement

To remove the bushing, place the impeller assembly in an arbor
press . Insert a 1/2” (12 .7mm) diameter plastic or wood dowel
through the eye of the impeller and press the bushing out . See
figure 26 .

To replace the bushing (item 3B), place the top of the impeller on
an arbor press with the thrust ring face down . Insert the front of
the bushing into the center of the impeller assembly & press into
place using a ¾” (19 mm) diameter plastic or wood dowel until
the bushing reaches the shoulder molded into the inner drive .
See figures 27, 28, 29 & 30 .

Figure 26

Figure 27

Figure 28

Figure 29

Figure 30

Section VI - Reassembly

1 . Place impeller assembly (item 3) into the motor adapter /

barrier (item 4) . See figure 31 .

2 . Install o-ring (item 2) onto housing (item 1) . Lubricate the o-
ring with P80 or a compatible lubricant . If o-ring will not
stay in place it may be necessary to roll the o-ring under

when installing it on the housing . See figure 32 .

3 . With the discharge port oriented in either a vertical

(12:00) or horizontal (3:00) position, align the holes of the

housing with the motor adapter / barrier . The flat side of the

motor adapter / barrier aligns with the motor feet or bottom

of the pump . See figures 33 & 34 . See note on page 4, step 3

of Mounting .

Figure 31

Figure 32

Figure 33

Vertical Discharge

Figure 34

Horizontal Discharge

4 . Push the housing with o-ring in place straight down to seat

the o-ring . Hold the housing in place & reinstall the (8) hous-

ing screws (item 7) in a star like pattern using the phillips

head screw driver . Hand tighten screws being careful not to

over tighten . See figure 35 .

5 . To complete the reassembly go to Section I – Assembly,

Pumps without Motors, Steps 4 - 10 .

Figure 35

Figure 22

Figure 23

7

NOTE: Install two long screws (item 7A) inserting one on

either side of the discharge nozzle .