Finish Thompson SP10 SERIES SELF-PRIMING User Manual

Page 13

Advertising
background image

13

Figure 34

Figure 35

8. Install the inner volute (item 7) by lining up the prongs

of the barrier with the channels in the inner volute.

Press down evenly until the prongs snap onto the sur-

face of the inner volute. See figures 36 and 37.

Figure 36

Figure 37

9. Install the separator plate (item 6) by lining up the

bottom opening of the inner volute with the opening in

the plate. Line up the slots in the separator plate with

the notches in the inner volute. See figure 38.

10. If the inner volute o-ring was removed previously,

lubricate the inner volute o-ring (item 5) with a chemi-

cally compatible lubricant, and install it in the groove

on the round suction nozzle in the center of the inner

volute. See figure 39.

Figure 38

Figure 39

11. After lubricating inside of gooseneck, install the hous-

ing (item 1). Line up the tab on the top of the separator

plate with the notch in the housing (located inside the

front of the housing near the discharge port). Using uni

form pressure, press the housing into place until it is

flush with the motor adapter. See figure 40. Install the

housing bolts, lock washers and flat washers (items 19,

20 & 21). Tighten all bolts evenly using a star pattern.

Tighten to 5 foot-lbs (6.8 N-m). Note: If bolt holes do

not line up, it may be necessary to tap the housing into

place with a rubber mallet. If still unable to line up the

bolt holes, then disassemble the pump down to the

barrier and start over from step 4.

12. Reinstall the pump on the motor/drive magnet follow-

ing instructions found in “Assembly, Pumps Without

Motors,” steps 7-10.

Figure 40

Advertising