Finish Thompson SP10 SERIES SELF-PRIMING User Manual

Page 8

Advertising
background image

8

Motor/Electrical
Install the motor according to NEC requirements and local

electrical codes. The motor should have an overload protec-

tion circuit.
Wire the motor for clockwise rotation when facing the fan

end of the motor.

CAUTION: Do not operate the pump to check rotation

until the pump is full of liquid.

Check all electrical connections with the wiring diagram

on the motor. Make sure the voltage, frequency, phase, and

amp draw comply with the supply circuit.
To verify correct rotation of the motor:
1. Install the pump into the system.
2. Remove the fill plug (items 2 & 2A) and fill the hous -

ing with 0.6 US gallon / 77 oz. (2.7 liters) of the service

liquid or water. Replace fill plug and tighten until the

o-ring is seated.

NOTE: Use a flexible spout funnel or a “tee” in the

discharge piping to fill the housing on pumps equipped

with flanges.

3. Fully open the suction and discharge valves.
4. Jog the motor (allow it to run for 1-2 seconds) and ob-

serve the rotation of the motor fan. Refer to the direc-

tional arrow molded into the front of the housing if

necessary.

NOTE: An SP pump running backwards may not

prime.

Section III - Start-up and Operation

1. Be sure the housing (item 1) has been filled with 0.6

US gallon / 77 oz. (2.7 liters) of service liquid and the

fill plug (item 2 & 2A) has been installed and tightened

until the o-ring is seated.

2. Open the inlet (suction) and outlet (discharge) valves

completely.

3. Turn the pump on. Wait for discharge pressure and flow

to stabilize (could take several minutes depending

upon suction lift). Adjust the flow rate and pressure by

regulating the discharge valve. Do not attempt to adjust

the flow with the suction valve.

Section IV - Shutdown

Turn off the motor.
NOTE: When the pump is stopped without a check valve

in the piping, liquid will flow through the pump returning

to the suction source. The SP design allows enough liquid

to be retained in the housing to allow repriming without

having to refill with liquid.

Flush Systems

CAUTION: Some fluids react with water; use compat-

ible flushing fluid.

1. Turn off the pump.
2. Completely close the suction and discharge valves.
3. Connect flushing fluid supply to flush inlet valve.
4. Connect flushing fluid drain to flush drain valve.
5. Open flushing inlet and outlet valves. Flush system

until the pump is clean.

NOTE: The drain can be used as the flushing drain

valve using appropriate customer supplied fittings. Us-

ing the drain helps to promote superior flushing and

draining results.

SP10 Priming Time Chart

1” (25.4 mm) Suction Piping

1.5” (38.1 mm) Suction Piping

Impeller

Diameter

Motor Speed

Motor Speed

3450 RPM

2900 RPM

3450 RPM

2900 RPM

Feet of Lift (sec.)

Meters of Lift (sec.)

Feet of Lift (sec.)

Meters of Lift (sec.)

in. (mm)

5

10

15

20

25

1.5

3.1

4.6

6.1

7.6

5

10

15

20

25

1.5

3.1

4.6

6.1

7.6

4.18 (106.2)

10

35

65

100

140

10

40

80

160 240

25

60

100

150

210

30

75

145

255

455

4.00 (101.6)

12

37

68

130

310

20

50

90

200 320

28

60

100

180

280

35

80

150

360

3.75 (95.3)

15

45

72

155

30

45

135

30

70

110

275

40

95

240

3.5 (88.9)

20

50

75

185

35

75

225

35

80

150

60

120

3.25 (82.6)

25

60

145

37

150

40

88

240

85

225

3 (76.2)

27

115

60

55

165

120

NOTE: Times shown are guidelines only. Times will vary based on system and piping setups.