Finish Thompson HVDP SERIES User Manual

Page 6

Advertising
background image

6

HVDP SERIES ASSEMBLY, MAINTENANCE & CLEANING INSTRUCTIONS

SECTION 1: MOTOR INSTALLATION AND REMOVAL

1. Check the rotation direction of the LR motor.

WARNING: Motor rotation must be clockwise when viewed from the fan end of the motor. Rotating the motor in the wrong direction

will cause damage to the pump.

2. Remove the motor adapter bolts (see Figure 2) and separate the motor adapter from the motor.

3. Thread the motor adapter onto the LR drive assembly. Hand tighten the motor adapter.

Note: Threads are left-handed. Also, thread lubricant is recommended to ensure smooth, bind free assembly.

4. The LR motor coupling consists of two 5/16” diameter pins welded to a hub. The LR drive assembly coupling has two slots that

receive these pins. Align the pins of the motor coupling with the slots on the drive assembly coupling and slide the motor onto

the drive assembly.

Note: Make sure the coupling is engaged properly and the motor adapter face is flush with the motor face.

5. Rotate the motor until the motor adapter mounting holes align with the threaded holes in the motor face.

6. Install the motor adapter bolts and torque to approximately 7 ft.-lbs. (9.5 N•M)

HVDP-LR REMOVAL:

1. Remove the LR motor adapter bolts.

2. Remove the LR motor.

INSTALLATION - HVDP-LR

Figure 1

Figure 2

INSTALLATION - HVDP-HR

1. Locate the rubber coupling insert that was separately shipped in a plastic bag (see Figure 1).

2. Install the rubber coupling insert onto the metal coupling half located on top of the HR drive

assembly.

3. Find the metal coupling half located inside the HR motor. Align this coupling with rubber insert

installed in the second step of these instructions.

4. Slide the HR motor onto the HR drive assembly.

5. Hand tighten the motor nut onto the threaded nose of the HR motor.

HVDP-HR REMOVAL: To remove the HR motor, reverse HR motor installation instructions

found in this section.

Advertising