OPERATING CONTROLS

(See Figures 2 & 8)

AC Power ON/OFF Switch

(Figure 2)

Turns AC Power to the Evolver MicroPak Con-

troller on or off.

MicroPak ON/OFF Switch

Turns 24VDC power to the MicroPak control unit

on or off.

MicroPak Power Indicator

Glows yellow when the MicroPak ON/OFF switch

is in the ON position.

μA Adjust Knob

Used to adjust the over-current setpoint in com-

bination with the View/Change Setpoint switch

when in local mode.

kV Adjust Knob

Used to adjust the kV setpoint when in local

mode.

Kilovolt Meter Display

Displays voltage in thousands of volts (kilovolts)

present at the applicator electrode.

High Voltage Ready Indicator

Glows yellow when High Voltage Ready to the

MicroPak is enabled.

>

This switch is located on the rear of the

controller.

NOTE

>

In local mode, with dipswitch SW3-3

OFF, the HV Ready Indicator will not light

until the high voltage is enabled.

NOTE

OPERATION

High Voltage ON Indicator

Glows red when high voltage to the applicator is

enabled.

High Voltage Enable/Fault Reset Switch

Enables high voltage to the applicator when mo-

mentarily moved to the ON position in local mode

with dipswitch SW3-3 off. If dipswitch SW3-3 is

ON high voltage enable is from the remote High

Voltage ON input instead. Also, resets faults

when momentarily moved to the OFF position.

CPU Indicator

Glows green whenever power is supplied to the

Discreet I/O Module.

Active Indicator

Glows green whenever the Discreet I/O Mod-

ule is communicating with the MicroPak Control

Unit.

Over-Current Fault Indicator

Glows yellow whenever the current from the ap-

plicator exceeds the over-current setpoint.

View/Change Setpoint Switch

Displays present current and voltage setpoints

when held in for 1 to 2 seconds. These settings

can be adjusted while the switch is held in as

follows:

When in local mode the kV setpoint is adjusted

using the kV adjust knob. When in remote mode

the kV setpoint is adjusted by changing the remote