Figure 9: Controller Top View

Table 2 - Ohmeter Measurements in Ohms from MicroPak Connector J3 through the

Low Voltage Cable to the Cascade

* - Meter reading may vary in the megohms range due to capacitance across pins.

From Wire 2 (white) 3 (red) 4 (black) 5 (green) 6 (blue)

9 (grn/yel)

10 (gray) 11 (orange) 16 (bare)

To Wire
2 (white)

XX

open ckt. open ckt. open ckt. open ckt. 19K - 21K 400K-600K 0 - 3

open ckt.

3 (red)

XX

0 - 3

0 - 3

0 - 3

open ckt.

open ckt.

open ckt. open ckt.*

4 (black)

XX

0 - 3

0 - 3

open ckt.

open ckt.

open ckt. open ckt.*

5 (green)

XX

0 - 3

open ckt.

open ckt.

open ckt. open ckt.*

6 (blue)

XX

open ckt.

open ckt.

open ckt. open ckt.*

9 (grn/yel)

XX

400K-600K 19K - 21K open ckt.

10 (gray)

XX

400K-600K open ckt.

11 (orange)

XX

open ckt.

16 (bare)

XX

Signal

IFB

Vct

Vct

DrB

DrA

SigGnd

kVFB

PLFB

VctRet

MicroPak Controller - Maintenance